A second muon telescope reduces bias in density measurements
Two telescopes measuring atmospheric muons simultaneously improved density estimates for aluminium and steel in a peer-reviewed laboratory study. One watched the target while the other supplied an open-sky reference, reducing shared flux changes that can masquerade as changes inside an object. The method still requires calibration and a suitable attenuation model; large field targets were not tested.
Science··Midday
Two telescopes separate the target from changing sky flux
Two telescopes watching atmospheric muons simultaneously improved laboratory density estimates. Cosmic-ray interactions in the atmosphere create muons. Their arrival rate at ground level changes over time. Counts behind an object therefore combine its attenuation of the particles with changes in the incoming flux. In the peer-reviewed study, one telescope viewed the target while another measured the sky as a simultaneous reference.[1]
Acrylic samples establish the density calculation
The apparatus used two similar scintillator telescopes, whose detectors give off light when particles pass. The team calibrated the pair without a target, then inserted acrylic samples of different thicknesses to establish the transmission relationship. Ratios of simultaneous counts suppressed flux changes shared by the instruments. The density measurements were carried out indoors using that calibration and an attenuation model suited to the tested materials.[1]
Blind aluminium and steel tests reduce bias
Aluminium and steel were then measured as blind targets. For aluminium, the paired result was 2.71 g/cm³ against the 2.70 g/cm³ reference; the steel estimate reached 7.48 g/cm³ against 7.90 g/cm³. Both agreed with the comparison values within the measurement uncertainties. The paired workflow reduced the bias seen when a single telescope’s target counts were compared with a background measurement acquired at another time.[1]